PRODUCT BULLETIN
Generic Copy

ISSUE DATE:18-Dec-2013
NOTIFICATION:15985
TITLE:MPC563XM REV. 2.1 2.2 ERRATA REPORTS
EFFECTIVE DATE:19-Dec-2013

DEVICE(S)
MPN
SPC5633MF1MLQ40
SPC5633MF1MLQ60
SPC5633MF1MLQ60R
SPC5633MF1MLQ80
SPC5633MF1MLQ80R
SPC5633MF2MLQ60
SPC5633MF2MLQ60R
SPC5633MF2MLQ80
SPC5633MF2MLU60
SPC5633MF2MLU80
SPC5634MF1MLQ60
SPC5634MF1MLQ60R
SPC5634MF1MLQ80
SPC5634MF1MLQX1
SPC5634MF1MLQX2
SPC5634MF1MLQX3
SPC5634MF1MLU60
SPC5634MF1MLU80
SPC5634MF1MLUX1
SPC5634MF1MLUX2
SPC5634MF1MLUX3
SPC5634MF1MMG80
SPC5634MF1MMGX1
SPC5634MF1MMGX2
SPC5634MF1MMGX3
SPC5634MF2MLQ60
SPC5634MF2MLQ60R
SPC5634MF2MLQ80
SPC5634MF2MLQ80R
SPC5634MF2MLQX1
SPC5634MF2MLQX2
SPC5634MF2MLQX3
SPC5634MF2MLU80
SPC5634MF2MLU80R
SPC5634MF2MLUX1
SPC5634MF2MLUX2
SPC5634MF2MLUX3
SPC5634MF2MMG80
SPC5634MF2MMGX1



AFFECTED CHANGE CATEGORIES
  • ERRATA


  • DESCRIPTION OF CHANGE

    The MPC563xM rev. 2.1 (1M35Y) and 2.2 (2M35Y) errata documentation has been updated to include additional errata that have been identified.

    The following errata have been added:
     
    6726       NPC: MCKO clock may be gated one clock period prior early when MCKO frequency is programmed as SYS_CLK/8 and gating is enabled
    7322       FlexCAN: Bus Off Interrupt bit is erroneously asserted when soft reset is performed while FlexCAN is in Bus Off state
    7352       DSPI: reserved bits in slave CTAR are writable
    7590       MPC563xM: Incorrect JTAG ID[MIC] and MIDR[S_F] register values
     
     
    The wording of the following erratum has changed:
     
    5086       eQADC: unexpected result may be pushed when Immediate Conversion Command is enabled
     

    The updated errata documentation is attached to this notice and can be found at:

    http://www.freescale.com/webapp/sps/site/prod_summary.jsp?code=MPC563xM&nodeId=01624606C1427E&fpsp=1&tab=Documentation_Tab

     



    REASON FOR CHANGE

    The errata documentation for MPC563xM rev. 2.1 (1M35Y) and 2.2 (2M35Y) has been updated.



    ANTICIPATED IMPACT OF PRODUCT CHANGE(FORM, FIT, FUNCTION, OR RELIABILITY)

    No changes have been made to the current production device.  The errata describe existing conditions identified on current production devices.  There are potential software implications to customers.




    NOTE:
    THE CHANGE(S) SPECIFIED IN THIS NOTIFICATION WILL BE IMPLEMENTED ON THE EFFECTIVE DATE LISTED ABOVE. To request further data or inquire about the notification, please enter a Service Request

    For sample inquiries - please go to www.freescale.com

    QUAL DATA AVAILABILITY DATE:     11-Dec-2013

    QUALIFICATION STATUS:     COMPLETED

    QUALIFICATION PLAN:

        N/A

    RELIABILITY DATA SUMMARY:

        N/A

    ELECTRICAL CHARACTERISTIC SUMMARY:

        N/A


    CHANGED PART IDENTIFICATION:

        N/A



    ATTACHMENT(S):
    External attachment(s) FOR this notification can be viewed AT:
    15985_MPC563XM_1M35Y.pdf
    15985_MPC563XM_2M35Y.pdf